CableBed – BS476 Class 0 Data Cable Floor Matting 13mm Thick x 575mm Wide

SKU: CableBed-flooring-575
  • Class 0 Fire Rating as per BS476 part 6/7 as below
  • BS476 part 6 1989 – low fire propagation, minimal heat contribution
  • BS476 part 7 1987 – no surface flame spread
  • CFC and HCFC Free
  • Closed Cell, Lightweight and Flexible
  • Prices below are for 14m x selected width rolls
  • Other widths and thickness’ available to order
  • To order or simply make your selection below or see our price list and data sheet and give us a call
  • Enquiries for Bulk Quantities or Repeating orders welcomed

From £80.51 Excl. VAT
You save (%)

Clear

This product is available for bespoke manufacturing, please choose an option below:

Class 0 Data Cable Floor Matting

Made from flexible closed cell, elastomeric, thermal insulation material, our cable matting can be cut on-site to provide a solution for varying paths to ensure the cables don’t become snagged, damaged through uneven floor levels, or caught on any pressure points. It protects them from moisture, including flooding that may come up through the concrete floor – the closed cell construction prevents chemical or moisture penetration from the concrete substance.

Product Characteristics

  • Flexible, lightweight closed cell rubber matting
  • Class ‘O’ fire category
  • Resists moisture from screeded floors
  • Ideal for laying beneath raised floors
  • Many other sizes available to order

SNO

Description

Test Methods

Specification

Results

1

Cellular Structure

Closed Cell

Closed Cell

2

Density (KG/M³)

ASTM D1667

50-70

50 to 70 kg/m³

3

Thermal Conductivity

a

@Mean Temp.9.36’C

ASTM C518:2010

W/(m.K)

0.0328 W(m.K)

b

@ Mean Temp. 24.77°C

ASTM C518:2010

W/(m.K)

0.0329 W(m.K)

c

@ Mean Temp. 46.39°C

ASTM C518:2010

W/(m.K)

0.0358 W(m.K)

d

Temperature Limits °C

ASTM C518:2010

-40°C to +105°C

98°C

4

Thermal Stability

ASTM C534

4.5(7days°F@200

4.1

5

Fire Resistance

Class O

BS 476 Part 6

Pass

a

Class 1

BS 476 Part 7

Pass

6

Fire and Smoke properties

AS/NZS 1530.3-1999

FSI 0-20;SDI 0-10

Pass

7

Water Absorption (% W/W)

ASTM C209: 1998

3.85

3.7

8

Long term water Absorption by total
immersion method (28 days)

BSEN12087:1997

AvgWA(Vol%)=1.0

9

Water Vapor Permeability-Perms

ASTM E96

0.1 perms-inch
max

0.1

10

Water Vapor Diffusion Factor(μ-value)

BSEN 12086:1997
TC:22±1’C&50±3%
RH

≥7000

≥7392

11

Smoke & Toxicity (IMO MSC
61(67) 1996

ISO 5659

Passed

Passed

12

Weather & UV Resistance

ASTM G53-1996

Excellent

Excellent

13

Ozone Resistance

ASTM D1149:1999

@40’C;72hr
duration
25% elongation

Excellent

14

Mildew Resistance

ASTM G 21-1980

No Fungal Growth

No Fungal Growth

15

Antimicrobial Activity

ISO22196:2007

No Bacteria
Recovered

99.99%

16

Chemical Resistance

ASTM C-871

Good

Excellent

17

VOC

ASTM D5116

<500ug/m2/hr

<6ug/m2/hr

18

Flexibility

Excellent

Excellent

19

Production Process

W/O CFC,
Asbestos, Chlorine,
& Fibre

Excellent

20

Sound Absorption (200HZ-2500HZ) SAA

ASTMC 423

NS

0.41

21

Noise Reduction Coefficient(NRC)

ASTMC 423

NS

0.4

22

Sound Absorption Coefficient (α)

ISO354:2003 &
ISO11654:1997

NS

αw=0.4

23

ODP & GWP

Bureu Veritas
Standard

ODP=0;GWP≤5

ODP=0;GWP<5

24

Storage Life:
To be stored in dry,clean
rooms @normalRH (50-70%)
with ambient temperature
10-35’C

In House

NA

NA

 

Product characteristics

  • Zero water vapor permeability and almost zero water
  • Good FR properties
  • ER22 NBR/PVC Sponge is CFC and HCFC free
  • No emissions of VOC

SNO

Description

Test Methods

Specification

Results

1

Cellular Structure

Closed Cell

Closed Cell

2

Density (KG/M³)

ASTM D1667

50-70

50 to 70 kg/m³

3

Thermal Conductivity

a

@Mean Temp.9.36’C

ASTM C518:2010

W/(m.K)

0.0328 W(m.K)

b

@ Mean Temp. 24.77°C

ASTM C518:2010

W/(m.K)

0.0329 W(m.K)

c

@ Mean Temp. 46.39°C

ASTM C518:2010

W/(m.K)

0.0358 W(m.K)

d

Temperature Limits °C

ASTM C518:2010

-40°C to +105°C

98°C

4

Thermal Stability

ASTM C534

4.5(7days°F@200

4.1

5

Fire Resistance

Class O

BS 476 Part 6

Pass

a

Class 1

BS 476 Part 7

Pass

6

Fire and Smoke properties

AS/NZS 1530.3-1999

FSI 0-20;SDI 0-10

Pass

7

Water Absorption (% W/W)

ASTM C209: 1998

3.85

3.7

8

Long term water Absorption by total
immersion method (28 days)

BSEN12087:1997

AvgWA(Vol%)=1.0

9

Water Vapor Permeability-Perms

ASTM E96

0.1 perms-inch
max

0.1

10

Water Vapor Diffusion Factor(μ-value)

BSEN 12086:1997
TC:22±1’C&50±3%
RH

≥7000

≥7392

11

Smoke & Toxicity (IMO MSC
61(67) 1996

ISO 5659

Passed

Passed

12

Weather & UV Resistance

ASTM G53-1996

Excellent

Excellent

13

Ozone Resistance

ASTM D1149:1999

@40’C;72hr
duration
25% elongation

Excellent

14

Mildew Resistance

ASTM G 21-1980

No Fungal Growth

No Fungal Growth

15

Antimicrobial Activity

ISO22196:2007

No Bacteria
Recovered

99.99%

16

Chemical Resistance

ASTM C-871

Good

Excellent

17

VOC

ASTM D5116

<500ug/m2/hr

<6ug/m2/hr

18

Flexibility

Excellent

Excellent

19

Production Process

W/O CFC,
Asbestos, Chlorine,
& Fibre

Excellent

20

Sound Absorption (200HZ-2500HZ) SAA

ASTMC 423

NS

0.41

21

Noise Reduction Coefficient(NRC)

ASTMC 423

NS

0.4

22

Sound Absorption Coefficient (α)

ISO354:2003 &
ISO11654:1997

NS

αw=0.4

23

ODP & GWP

Bureu Veritas
Standard

ODP=0;GWP≤5

ODP=0;GWP<5

24

Storage Life:
To be stored in dry,clean
rooms @normalRH (50-70%)
with ambient temperature
10-35’C

In House

NA

NA

 

Product characteristics

  • Zero water vapor permeability and almost zero water
  • Good FR properties
  • ER22 NBR/PVC Sponge is CFC and HCFC free
  • No emissions of VOC
Rubber Gaskets Quote Request
Cut Rubber Strips Quote Request
Cut Rubber Parts Quote Request