LinkedIn Tracking CoruGlass Clear Vinyl | Flame Retardant to DIN53382/DIN4102 B2 | Coruba Skip to content
Free delivery on orders over £1200.00, all other orders have a fixed rate of £20.00 + VAT.
*Terms and conditions apply

If you would like to discuss this product, or you require a sample, please call 01702 560194. Alternatively, you can use our contact form.

Please note: All cut material is non-returnable unless faulty as these are non-sellable and have been cut to specific requirements.

CoruGlass Clear Vinyl | Flame Retardant to DIN53382/DIN4102 B2

SKU: CoruGlass
  • Made exclusively of non-phthalate plasticisers
  • Self-extinguishing flame retardant properties
  • High transparency, uv resistance and durability

From £5.61 Excl. VAT
You save (%)

Clear

CoruGlass Flame Retardant protective sheeting ranges from 0.3mm to 1mm in thickness. Offering the greatest transparency on the market, it is made exclusively of non-phthalate plasticisers. This is an extremely important factor, since it means the product does minimal harm to humans or the environment, compared with other products of a similar nature.

Flame retardant, our CoruGlass Flame Retardant film provides the preferred solution for numerous applications, thanks to its high transparency, UV resistance and durability.

As well as being used for protective sheets in the fight against viruses, it is ideal for other applications such as tents, marquees, porch roofs, boats (including awning), terraces, canopies, doors, windows, cars, yachts and any partition.

Property Test method/method Technical data
Colour Clear
Density DIN 53479/A 1.25g/cc+/-0.05
Tear strength ISO 6383-1:1983 Crosswide: 46.5N/mm
Lengthways: 38.5N/mm
Tensile strength Test ISO527-1:2012

&ISO 527-3:1995/Cor. 2:2001

crosswide: 20.1mpa
Lengthways: 21.2mpa
Elongation at break: ISO527-1:2012

&ISO 527-3:1995/Cor. 2:2001

crosswide: 292%
Lengthways: 275%
Flammability DIN 53382/DIN4102/B2 Normally flammable B2
Edge fire behaviour DIN53382/2/DIN4102/B2 Self-extinguishing
Fire Behaviour DIN53382/2/DIN4102/B2 Doesn’t continue to burn or smoulder

TEST RESULTS:

These tests are conducted in DIN4102-1 Clause 6.2 Class B2 materials according to the application.

1 Samples details

Materials/colour PVC/Transparent
Thickness 2mm
2 Test Conditions
Temperature Relative Humidity Duration
Precondition T=23+/-2 ℃ (50+/-6)% 8 days

3 Test requirements

Class B2: This test shall be deemed passed if for any of the five specimens tested flaming does not reach the gauge mark within 20 seconds after flame application, either with bottom edge ignition or surface ignition.

4 Test Result

The test result was obtained using the specified test condition and not necessarily represent the behaviour of the test material under other conditions of test or use.

Parameter

Result

Bottom Edge Ignition

Surface Ignition

1

2

3

4

5

6

7

8

9

10

Specimen Ignition Y/N

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Ignition Ceased Time

If flame tip reached

150mm

Line/40, 190mm line

NO NO NO NO NO NO NO NO NO NO

DIN4102-1B2 TEST RESULT

Ignition time to reached 150mm

line/40,190mm line

Filter paper

ignition

NO NO NO NO NO NO NO NO NO NO

Remark:*— The specimen was ignited but self-extinguished after removed from the burner.

Property Test method/method Technical data
Colour Clear
Density DIN 53479/A 1.25g/cc+/-0.05
Tear strength ISO 6383-1:1983 Crosswide: 46.5N/mm
Lengthways: 38.5N/mm
Tensile strength Test ISO527-1:2012

&ISO 527-3:1995/Cor. 2:2001

crosswide: 20.1mpa
Lengthways: 21.2mpa
Elongation at break: ISO527-1:2012

&ISO 527-3:1995/Cor. 2:2001

crosswide: 292%
Lengthways: 275%
Flammability DIN 53382/DIN4102/B2 Normally flammable B2
Edge fire behaviour DIN53382/2/DIN4102/B2 Self-extinguishing
Fire Behaviour DIN53382/2/DIN4102/B2 Doesn’t continue to burn or smoulder

TEST RESULTS:

These tests are conducted in DIN4102-1 Clause 6.2 Class B2 materials according to the application.

1 Samples details

Materials/colour PVC/Transparent
Thickness 2mm
2 Test Conditions
Temperature Relative Humidity Duration
Precondition T=23+/-2 ℃ (50+/-6)% 8 days

3 Test requirements

Class B2: This test shall be deemed passed if for any of the five specimens tested flaming does not reach the gauge mark within 20 seconds after flame application, either with bottom edge ignition or surface ignition.

4 Test Result

The test result was obtained using the specified test condition and not necessarily represent the behaviour of the test material under other conditions of test or use.

Parameter

Result

Bottom Edge Ignition

Surface Ignition

1

2

3

4

5

6

7

8

9

10

Specimen Ignition Y/N

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Ignition Ceased Time

If flame tip reached

150mm

Line/40, 190mm line

NO NO NO NO NO NO NO NO NO NO

DIN4102-1B2 TEST RESULT

Ignition time to reached 150mm

line/40,190mm line

Filter paper

ignition

NO NO NO NO NO NO NO NO NO NO

Remark:*— The specimen was ignited but self-extinguished after removed from the burner.

Rubber Gaskets Quote Request
Cut Rubber Strips Quote Request
Cut Rubber Parts Quote Request